Current Auctions

Used GE LM2500-PE Combined-Cycle Cogeneration Plant Rated at 28 MW, Auction Details

2600 De La Cruz Blvd.
Santa Clara, CA 95050
Used GE LM2500-PE Combined-Cycle Cogeneration Plant Rated at 28 MW

Sale Date: TBD

Inspection Date: Inspection is by appointment only

*****************************************************************************************

Major Components of the Plant together with:

Water Treatment Units Compressors Oil Cooling Unit Duct Burners Fire Protection System Nox Metering Water Pumps Wash Skid Starting Skid

Highlights

Santa Clara Co Gen Plant powerpoint

MAJOR COMPONENTS OF THE PLANT

  • GE LM2500-PE Steam Injected Gas Turbine Generator Set with a 2 Pole Alternator Rated at 33,700 KVA, 13,800 Volts, 60 Hz, 3600 Rpm
  • Vogt HRSG rated at 125,000 Lb/Hr, Super Heated Steam at 600 PSI, 750 Degrees F
  • 4950 KW Back Pressure Non Condensing 7-Stage Steam Turbine Generator with Inlet Steam Conditions at 600 PSI, 750 F and Duel Extraction at 200 PSI and 70 PSI, with Air Cooled GE Canada Generator 13,800 Volts, 4 Pole, 1800 Rpm

ANCILLARY EQUIPMENT

  • 2 US Filter Reverse Osmosis Water Treatment Units
  • Natural Gas Compressors
  • Oil Cooling Unit
  • GE Mark IV Controls
  • Plc Controlled HRSG Duct Burners
  • Fire Protection System
  • Nox Metering
  • Boiler Feed Water Pumps
  • On And Off Line Wash Skid
  • Electro-Hydraulic Starting Skid

PLANT HISTORY

  • Plant is Currently Running and Gas Turbine Generator Recently Had Power Turbine Overhaul and Installed in 4/2017 and The Gas Turbine Engine # 481-766 has 47,931 Hours Since Last Major Overhaul.

 